O W N E R ’ S M A N U A L
RMX 6
6-CHANNEL MIC/LINE RACK MIXER
WARNING
An equilateral triangle enclosing a lightening flash/arrowhead symbol is
intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclosure which may be of sufficient
magnitude to constitute a risk of electric shock.
ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
An equilateral triangle enclosing an exclamation point is intended to alert
the user to the presence of important operating and service instructions in
the literature enclosed with this unit.
IMPORTANT SAFETY INSTRUCTIONS
When using this electronic device, basic precautions should always be taken, including the following:
1. Read all instructions before using the product.
2. Do not use this product near water (e.g., near a bathtub, washbowl, kitchen sink, in a wet basement, or near a swimming
pool, etc.).
3. This product should be used only with a cart or stand that will keep it level and stable and prevent wobbling.
4. This product, in combination with headphones or speakers, may be capable of producing sound levels that could cause
permanent hearing loss. Do not operate for a long period of time at a high volume level or at a level that is uncomfortable.
If you experience any hearing loss or ringing in the ears, you should consult an audiologist.
5. The product should be positioned so that proper ventilation is maintained.
6. The product should be located away from heat sources such as radiators, heat vents, or other devices
(including amplifiers) that produce heat.
7. The product should be connected to a power supply only of the type described in the operating instructions or as marked on the
product. Replace the fuse only with one of the specified type, size, and correct rating.
8. The power supply cord should: (1) be undamaged, (2) never share an outlet or extension cord with other devices so that the
outlet’s or extension cord’s power rating is exceeded, and (3) never be left plugged into the outlet when not being used for
a long period of time.
9. Care should be taken so that objects do not fall into, and liquids are not spilled through, the enclosure’s openings.
10. The product should be serviced by qualified service personnel if:
A.
B.
C.
D.
E.
The power supply cord or the plug has been damaged.
Objects have fallen into, or liquid has been spilled onto the product.
The product has been exposed to rain.
The product does not appear to operate normally or exhibits a marked change in performance.
The product has been dropped, or the enclosure damaged.
11. Do not attempt to service the product beyond what is described in the user maintenance instructions. All other servicing should
be referred to qualified service personnel.
3
INSTALLATION
To ensure years of enjoyment from your NADY AUDIO RMX 6 please read and understand this manual thoroughly before
using the unit.
INSPECTION
Your RMX 6 was carefully packed at the factory in packaging designed to protect the units in shipment. Before installing and using your
unit, carefully examine the packaging and all contents for any signs of physical damage that may have occurred in transit.
(Note: Nady Systems is not responsible for shipping damage. If the unit is damaged, do not return to us, but notify your dealer and the
shipping company immediately to make a claim. Such claims must be made by the consignee in a timely manner.)
CONTENTS:
• Instruction manual
• SDP-20 (verify that the unit’s serial number is same as shown on shipping carton)
• AC Power cord
• Warranty Card
RACK MOUNTING
The RMX 6 fits into one standard 19" rack unit of space (1 3/4"). Parts of the unit can become very warm during use. This is normal
during operation. Care should be taken to ensure that there is enough space around the unit for cooling (at least 12” or 30cm). Do not
place the RMX 6 on high temperature devices such as power amplifiers, etc., or the unit may overheat in operation. Also, do not place
the unit on speakers as this may cause them to move and/or fall due to speaker vibrations.
Although the unit’s chassis is shielded against radio frequency (RF) and electromagnetic interference (EMI), extremely high fields of RF
and EMI should be avoided.
POWER CONNECTION
The RMX 6 has an internal power supply and is designed to operate from an external AC source. Power requirements for electrical
equipment differ from area to area. Be sure to confirm that the voltage selected by the voltage selector switch on the back panel is
proper for your area (120VAC/60 Hz or 230VAC/50Hz) per the information below:
Europe (except UK): 230V, 50Hz
UK and Australia: 240V, 50Hz
USA and Canada: 120V, 60 Hz
For other areas, please check with local authorities.
When ready to operate, plug the AC cord into the power source. Make sure that the unit is turned off before connecting to the AC
power source to avoid possible loud transients which can damage your speakers or your ears, especially when monitoring with
headphones.
4
CONTROLS AND CONNECTORS
FRONT PANEL
(4)
(3)
(2)
(1)
REAR PANEL
(5)
(6)
(7)
(8)
(9)
Front Panel
(1) POWER SWITCH
(3) MASTER LEVEL CONTROL
Use this switch to power unit ON or OFF. The integrated LED will
light when the unit is ON. Before turning on this unit, verify
connection to the proper voltage AC source, check all connections
and turn down the level controls of equipment connected to the
outputs.
Adjusts the master level of the combined individual channel signals
(4) CHANNEL GAIN CONTROLS
Adjust the individual (1-6) channel gains
(2) BASS & TREBLE TONE CONTROLS
Adjust the relative balance of bass and treble
Rear Panel
(8) MIXER OUTPUTS
Unbalanced 1/4" (6.3mm) and balanced XLR outputs
(Note: Only one output (1/4" or XLR) can be used at one time. Do
not connect to both at the same time, or the signal will be severely
distorted.)
(5) AC POWER CORD IEC CONNECTOR WITH INTEGRATED
FUSE HOLDER
This standard IEC power cord receptacle is used to connect the
AC power to your unit. It features a built-in fuse holder for a
5X20mm, 0.5A/250V slow-blow fuse. If the fuse continuously
blows, shut of the unit and have it serviced by qualified service
personnel.
(9) MIXER INPUTS
Unbalanced 1/4"(6.3mm) and balanced XLR inputs for channels 1
through 6.
(Note: Channels 4, 5 and 6 provide +15V phantom power for
condenser mics. These can be safely used with any balanced
dynamic mic also; however, do not connect any unbalanced
dynamic microphones to the XLR balanced inputs as they may be
damaged.)
(6) AC VOLTAGE SELECT SWITCH
Before plugging in the power cord, check to see that the unit is
set for the proper voltage for your area: ~115V (60Hz) or ~230V
(50Hz).
(Note: Use at the improper voltage can damage your unit and
void the warranty.)
(Note: Only one input per each channel (1/4" or XLR) can be used
at one time. Do not connect to both at the same time or the signal
will be severely distorted.)
(7) HIGH/LOW OUTPUT LEVEL SELECT SWITCH
Selects either high or low output so the level can be optimized for
the connected audio equipment (amp, recording device, etc.)
5
SPECIFICATIONS
Frequency Response:............................................................................................... 10Hz—20KHz +/-3dB
Total Harmonic Distortion (THD) + Noise: .............................................................. 0.1%
S/N Ratio: ................................................................................................................... >60dB
Tone Controls
Bass:........................................................................................................................... +/-12dB / 100Hz
Treble:......................................................................................................................... +/-12dB / 10KHz
Inputs: ........................................................................................................................ 6 X MIC (level/impedance): Balanced: 3mV
.................................................................................................................................... 6 X LINE(level/impedance): Unbalanced: 100mV
Outputs (All controls flat)
High Output: .............................................................................................................. 1.5V
Low Output: ............................................................................................................... 0.5V
Impedance (1/4"): ...................................................................................................... 600 ohms
(XLR):..................................................................................................... 600 ohms
LED indicator:............................................................................................................ Power ON
Fuse Requirements, Type and Size:........................................................................ T250mA, 5X20mm glass type
Dimensions:............................................................................................................... 19" x 1.75" x 8" (483 x 44 x 203mm)
Weight: ....................................................................................................................... 7.0 lbs.( 3.2 Kg)
The specifications above are correct at the time of printing of this manual. For improvement purposes, all specifications for this unit,
including design and appearance, are subject to change without prior notice.
LEGAL INFORMATION
NOTICE
The information in this document is subject to change, as the Company may make changes to product in order to improve reliability,
design, or function, without prior written notice. No part of this manual may be reproduced or transmitted in any form or by any means
without the written permission of the company.
IN NO EVENT WILL THE COMPANY BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER
ARISING DIRECTLY OR INDIRECTLY, SUCH AS LOSS OF PROFIT OR GOOD WILL, THAT MAY BE SUFFERED IN CONNECTION
WITH THE PURCHASE OF THIS PRODUCT OR FROM THE BREACH OF ANY REPRESENTATION OR WARRANTY.
LICENSE
The Company grants the customer a non-exclusive, non-transferable license to use the software, if any, accompanying this product for
internal use on a single computer system. The end user may make a single copy of the software solely for backup purposes; otherwise,
no copies may be made of the software or any part thereof. No other license of any kind is granted to any part of the product or any of
the intellectual property therein.
6
NOTES
7
SERVICE FOR YOUR NADY AUDIO PRODUCT
(U.S.) Should your NADY AUDIO product require service, please contact the Nady Service Department via telephone
at (510) 652-2411, or e-mail at service@nady.com.
(International) For service, please contact the NADY AUDIO distributor in your country through the dealer from
whom you purchased this product.
DO NOT ATTEMPT TO SERVICE THIS UNIT
YOURSELF AS IT CAN BE DANGEROUS AND
WILL ALSO VOID THE WARRANTY.
NADY SYSTEMS, INC. • 6701 SHELLMOUND STREET, EMERYVILLE, CA 94608
|
Miller Electric Welder AA40GBU User Manual
NEC Car Video System LCD 70 Series User Manual
NEC Projector VT440 VT540 User Manual
NETGEAR Network Router RT210 User Manual
NewAir Water Heater APH 4000PV User Manual
Nextar Digital Photo Frame N3 506 User Manual
Omron Blood Pressure Monitor Hem 907XL User Manual
Optoma Technology Projector EzPro 750 User Manual
Palm PDAs Smartphones Visor Neo User Manual
Palsonic CRT Television 5130GM User Manual