Nady Systems Music Mixer RMX6 User Manual

O W N E R ’ S M A N U A L  
RMX 6  
6-CHANNEL MIC/LINE RACK MIXER  
 
WARNING  
An equilateral triangle enclosing a lightening flash/arrowhead symbol is  
intended to alert the user to the presence of uninsulated dangerous  
voltagewithin the products enclosure which may be of sufficient  
magnitude to constitute a risk of electric shock.  
ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR  
An equilateral triangle enclosing an exclamation point is intended to alert  
the user to the presence of important operating and service instructions in  
the literature enclosed with this unit.  
IMPORTANT SAFETY INSTRUCTIONS  
When using this electronic device, basic precautions should always be taken, including the following:  
1. Read all instructions before using the product.  
2. Do not use this product near water (e.g., near a bathtub, washbowl, kitchen sink, in a wet basement, or near a swimming  
pool, etc.).  
3. This product should be used only with a cart or stand that will keep it level and stable and prevent wobbling.  
4. This product, in combination with headphones or speakers, may be capable of producing sound levels that could cause  
permanent hearing loss. Do not operate for a long period of time at a high volume level or at a level that is uncomfortable.  
If you experience any hearing loss or ringing in the ears, you should consult an audiologist.  
5. The product should be positioned so that proper ventilation is maintained.  
6. The product should be located away from heat sources such as radiators, heat vents, or other devices  
(including amplifiers) that produce heat.  
7. The product should be connected to a power supply only of the type described in the operating instructions or as marked on the  
product. Replace the fuse only with one of the specified type, size, and correct rating.  
8. The power supply cord should: (1) be undamaged, (2) never share an outlet or extension cord with other devices so that the  
outlets or extension cords power rating is exceeded, and (3) never be left plugged into the outlet when not being used for  
a long period of time.  
9. Care should be taken so that objects do not fall into, and liquids are not spilled through, the enclosures openings.  
10. The product should be serviced by qualified service personnel if:  
A.  
B.  
C.  
D.  
E.  
The power supply cord or the plug has been damaged.  
Objects have fallen into, or liquid has been spilled onto the product.  
The product has been exposed to rain.  
The product does not appear to operate normally or exhibits a marked change in performance.  
The product has been dropped, or the enclosure damaged.  
11. Do not attempt to service the product beyond what is described in the user maintenance instructions. All other servicing should  
be referred to qualified service personnel.  
3
 
INSTALLATION  
To ensure years of enjoyment from your NADY AUDIO RMX 6 please read and understand this manual thoroughly before  
using the unit.  
INSPECTION  
Your RMX 6 was carefully packed at the factory in packaging designed to protect the units in shipment. Before installing and using your  
unit, carefully examine the packaging and all contents for any signs of physical damage that may have occurred in transit.  
(Note: Nady Systems is not responsible for shipping damage. If the unit is damaged, do not return to us, but notify your dealer and the  
shipping company immediately to make a claim. Such claims must be made by the consignee in a timely manner.)  
CONTENTS:  
Instruction manual  
SDP-20 (verify that the units serial number is same as shown on shipping carton)  
AC Power cord  
Warranty Card  
RACK MOUNTING  
The RMX 6 fits into one standard 19" rack unit of space (1 3/4"). Parts of the unit can become very warm during use. This is normal  
during operation. Care should be taken to ensure that there is enough space around the unit for cooling (at least 12or 30cm). Do not  
place the RMX 6 on high temperature devices such as power amplifiers, etc., or the unit may overheat in operation. Also, do not place  
the unit on speakers as this may cause them to move and/or fall due to speaker vibrations.  
Although the units chassis is shielded against radio frequency (RF) and electromagnetic interference (EMI), extremely high fields of RF  
and EMI should be avoided.  
POWER CONNECTION  
The RMX 6 has an internal power supply and is designed to operate from an external AC source. Power requirements for electrical  
equipment differ from area to area. Be sure to confirm that the voltage selected by the voltage selector switch on the back panel is  
proper for your area (120VAC/60 Hz or 230VAC/50Hz) per the information below:  
Europe (except UK): 230V, 50Hz  
UK and Australia: 240V, 50Hz  
USA and Canada: 120V, 60 Hz  
For other areas, please check with local authorities.  
When ready to operate, plug the AC cord into the power source. Make sure that the unit is turned off before connecting to the AC  
power source to avoid possible loud transients which can damage your speakers or your ears, especially when monitoring with  
headphones.  
4
 
CONTROLS AND CONNECTORS  
FRONT PANEL  
(4)  
(3)  
(2)  
(1)  
REAR PANEL  
(5)  
(6)  
(7)  
(8)  
(9)  
Front Panel  
(1) POWER SWITCH  
(3) MASTER LEVEL CONTROL  
Use this switch to power unit ON or OFF. The integrated LED will  
light when the unit is ON. Before turning on this unit, verify  
connection to the proper voltage AC source, check all connections  
and turn down the level controls of equipment connected to the  
outputs.  
Adjusts the master level of the combined individual channel signals  
(4) CHANNEL GAIN CONTROLS  
Adjust the individual (1-6) channel gains  
(2) BASS & TREBLE TONE CONTROLS  
Adjust the relative balance of bass and treble  
Rear Panel  
(8) MIXER OUTPUTS  
Unbalanced 1/4" (6.3mm) and balanced XLR outputs  
(Note: Only one output (1/4" or XLR) can be used at one time. Do  
not connect to both at the same time, or the signal will be severely  
distorted.)  
(5) AC POWER CORD IEC CONNECTOR WITH INTEGRATED  
FUSE HOLDER  
This standard IEC power cord receptacle is used to connect the  
AC power to your unit. It features a built-in fuse holder for a  
5X20mm, 0.5A/250V slow-blow fuse. If the fuse continuously  
blows, shut of the unit and have it serviced by qualified service  
personnel.  
(9) MIXER INPUTS  
Unbalanced 1/4"(6.3mm) and balanced XLR inputs for channels 1  
through 6.  
(Note: Channels 4, 5 and 6 provide +15V phantom power for  
condenser mics. These can be safely used with any balanced  
dynamic mic also; however, do not connect any unbalanced  
dynamic microphones to the XLR balanced inputs as they may be  
damaged.)  
(6) AC VOLTAGE SELECT SWITCH  
Before plugging in the power cord, check to see that the unit is  
set for the proper voltage for your area: ~115V (60Hz) or ~230V  
(50Hz).  
(Note: Use at the improper voltage can damage your unit and  
void the warranty.)  
(Note: Only one input per each channel (1/4" or XLR) can be used  
at one time. Do not connect to both at the same time or the signal  
will be severely distorted.)  
(7) HIGH/LOW OUTPUT LEVEL SELECT SWITCH  
Selects either high or low output so the level can be optimized for  
the connected audio equipment (amp, recording device, etc.)  
5
 
SPECIFICATIONS  
Frequency Response:............................................................................................... 10Hz20KHz +/-3dB  
Total Harmonic Distortion (THD) + Noise: .............................................................. 0.1%  
S/N Ratio: ................................................................................................................... >60dB  
Tone Controls  
Bass:........................................................................................................................... +/-12dB / 100Hz  
Treble:......................................................................................................................... +/-12dB / 10KHz  
Inputs: ........................................................................................................................ 6 X MIC (level/impedance): Balanced: 3mV  
.................................................................................................................................... 6 X LINE(level/impedance): Unbalanced: 100mV  
Outputs (All controls flat)  
High Output: .............................................................................................................. 1.5V  
Low Output: ............................................................................................................... 0.5V  
Impedance (1/4"): ...................................................................................................... 600 ohms  
(XLR):..................................................................................................... 600 ohms  
LED indicator:............................................................................................................ Power ON  
Fuse Requirements, Type and Size:........................................................................ T250mA, 5X20mm glass type  
Dimensions:............................................................................................................... 19" x 1.75" x 8" (483 x 44 x 203mm)  
Weight: ....................................................................................................................... 7.0 lbs.( 3.2 Kg)  
The specifications above are correct at the time of printing of this manual. For improvement purposes, all specifications for this unit,  
including design and appearance, are subject to change without prior notice.  
LEGAL INFORMATION  
NOTICE  
The information in this document is subject to change, as the Company may make changes to product in order to improve reliability,  
design, or function, without prior written notice. No part of this manual may be reproduced or transmitted in any form or by any means  
without the written permission of the company.  
IN NO EVENT WILL THE COMPANY BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER  
ARISING DIRECTLY OR INDIRECTLY, SUCH AS LOSS OF PROFIT OR GOOD WILL, THAT MAY BE SUFFERED IN CONNECTION  
WITH THE PURCHASE OF THIS PRODUCT OR FROM THE BREACH OF ANY REPRESENTATION OR WARRANTY.  
LICENSE  
The Company grants the customer a non-exclusive, non-transferable license to use the software, if any, accompanying this product for  
internal use on a single computer system. The end user may make a single copy of the software solely for backup purposes; otherwise,  
no copies may be made of the software or any part thereof. No other license of any kind is granted to any part of the product or any of  
the intellectual property therein.  
6
 
NOTES  
7
 
SERVICE FOR YOUR NADY AUDIO PRODUCT  
(U.S.) Should your NADY AUDIO product require service, please contact the Nady Service Department via telephone  
at (510) 652-2411, or e-mail at service@nady.com.  
(International) For service, please contact the NADY AUDIO distributor in your country through the dealer from  
whom you purchased this product.  
DO NOT ATTEMPT TO SERVICE THIS UNIT  
YOURSELF AS IT CAN BE DANGEROUS AND  
WILL ALSO VOID THE WARRANTY.  
NADY SYSTEMS, INC. 6701 SHELLMOUND STREET, EMERYVILLE, CA 94608  
Tel: 510.652.2411 Fax: 510.652.5075 www.nady.com  
 

Miller Electric Welder AA40GBU User Manual
NEC Car Video System LCD 70 Series User Manual
NEC Projector VT440 VT540 User Manual
NETGEAR Network Router RT210 User Manual
NewAir Water Heater APH 4000PV User Manual
Nextar Digital Photo Frame N3 506 User Manual
Omron Blood Pressure Monitor Hem 907XL User Manual
Optoma Technology Projector EzPro 750 User Manual
Palm PDAs Smartphones Visor Neo User Manual
Palsonic CRT Television 5130GM User Manual